Guide, Platform
How to calculate your corporate carbon footprint
- Author
- PureField
- Published
- Updated
A corporate carbon footprint is the total greenhouse gas emissions a company causes in one year, expressed in tonnes of CO₂ equivalent (t CO₂e). To calculate it, multiply each source's activity data (kWh, litres, kg, km) by its emission factor, then add the results up under the GHG Protocol's Scope 1, 2 and 3 and, if needed, the six categories of ISO 14064-1.
Who calculates a carbon footprint, and why?
Companies calculate their carbon footprint for four reasons: mandatory reporting, data requests from customers who report, exports to the European Union, and reduction targets.
The finance manager of a company that makes air conditioners and services them gets an email from a buyer in Germany. The buyer wants last year's Scope 1 and 2 emissions and the share that falls on its own purchases. The company has the invoices, the fuel card statements and the service reports, but they have never been added up in one table.
- Mandatory reporting: Companies within the scope of TSRS, Türkiye's sustainability reporting standards, disclose Scope 1, 2 and 3 in their sustainability report.
- Customer requests: Their suppliers receive data requests for Scope 3. The GHG Protocol's Scope 3 technical guidance describes the most supplier-specific method for purchased goods and services as collecting product-level cradle-to-gate inventory data from suppliers; under the hybrid method, the customer asks the supplier for its allocated share of Scope 1 and 2.
- Exports: An EU importer asks the producer of iron and steel, aluminium, cement or fertiliser for the embedded emissions of the goods.
- Reduction targets: A company setting a target first builds a base-year inventory as its starting point.
In the example below, a mid-sized manufacturing and service company comes to 570 tonnes of CO₂e. The lower limit for installations in Türkiye's Emissions Trading System is 50,000 tonnes a year. A company of this size does the calculation for its customers' data requests and its own reduction target.
Which standards apply?
The two main frameworks for a company-level calculation are the GHG Protocol Corporate Standard and ISO 14064-1:2018. Both use the same data and group the results differently.
The GHG Protocol splits emissions into three scopes. Scope 1 is direct emissions from sources the company owns or controls: boilers, furnaces, company vehicles, gas leaking from its own cooling equipment. Scope 2 is emissions from generating the electricity, steam and heat the company buys and uses. Scope 3 is all other indirect emissions in the value chain. The Corporate Standard requires Scope 1 and 2 to be accounted for and reported separately and leaves Scope 3 optional. The Scope 3 Standard divides those emissions into 15 categories, eight upstream and seven downstream.
ISO 14064-1:2018 groups emissions into six categories. It requires direct emissions to be quantified separately by gas, significant indirect emissions to be selected with documented criteria, and uncertainty to be assessed at category level. In Türkiye, TSRS 2 also requires measurement under the GHG Protocol Corporate Standard unless an authority requires a different method.
| GHG Protocol | ISO 14064-1 category | Example in a service and manufacturing company |
|---|---|---|
| Scope 1 | 1. Direct emissions | Gas boiler and furnace, service vehicle fuel, forklift LPG, refrigerant leaking from the company's own equipment |
| Scope 2 | 2. Imported energy | Purchased electricity, steam and heat |
| Scope 3, categories 4, 6, 7 and 9 | 3. Transportation | Purchased freight, business travel, employee commuting |
| Scope 3, categories 1, 2, 3 and 5 | 4. Products used by the organization | Purchased materials and services, capital goods, well-to-tank emissions of fuels, waste |
| Scope 3, categories 11 and 12 | 5. Use of products from the organization | Lifetime energy use and refrigerant leaks of sold equipment, end of life |
| Other company-specific items | 6. Other sources | Sources that fit no other category |
What to watch when drawing the boundaries
A boundary drawn wrongly counts the same emission twice or not at all. Three decisions matter most.
- Consolidation approach: The GHG Protocol defines the equity share, financial control and operational control approaches. Emissions from leased service vehicles count as direct under the operational control approach and stay indirect under financial control.
- Who owns the refrigerant: Gas leaking from equipment a company owns or controls is that company's Scope 1. Gas topped up in a customer's air conditioner is the customer's Scope 1; the service company's inventory takes the leaks from its own equipment. For a manufacturer that sells air conditioning or refrigeration equipment, leaks from the sold units during use belong to Scope 3 category 11.
- Montreal gases: HCFCs such as R-22 are not Kyoto Protocol gases. The GHG Protocol allows them to be reported separately, outside the scopes. In the DESNZ 2026 table, the row for R-22 that counts only Kyoto gases is empty; the row that counts non-Kyoto gases gives 1,760 kg CO₂e/kg.
How does the calculation work, step by step?
Every source uses the same formula: Emissions (kg CO₂e) = activity data × emission factor. For refrigerants the factor is the gas's global warming potential (GWP): every kilogram that leaks equals that many kilograms of CO₂. If leaks are not measured separately, DESNZ describes using the year's top-ups instead, since the gas added to a unit replaces what leaked out.
- Boundary: which companies, sites and vehicles are in; a 12-month reporting period; the consolidation approach.
- Source list: all of Scope 1 and 2; the significant Scope 3 categories and the reasons for any exclusions.
- Activity data: kWh and m³ from invoices, litres from the fuel card, refrigerant kilograms from service forms, passenger-km from travel statements.
- Factor set: one source and one GWP set; write the source and year of the grid factor into the report.
- Calculation: line-by-line multiplication, then totals by scope and category.
- Documentation: assumptions, data sources, the uncertainty assessment and the base year.
Three reference results with DESNZ 2026 factors:
- 100,000 kWh of natural gas × 0.18231 = 18,231 kg, or 18.23 t CO₂e
- 1,000 L of diesel × 2.66155 = 2,661.55 kg, or 2.66 t CO₂e
- 10 kg R-410A top-up × 1,924 = 19,240 kg, or 19.24 t CO₂e
The last line shows why refrigerant deserves its own tracking: 10 kg of R-410A equals burning about 7,229 litres of diesel.
On a Turkish gas invoice, kWh are found by multiplying the gas volume by its gross (upper) calorific value (Natural Gas Market Tariffs Regulation, Article 18). The DESNZ kWh factor on a gross calorific value basis therefore applies to the invoice directly. If only the volume is known, 2.02633 kg CO₂e/m³ can be used; kWh is preferred because it reflects the actual calorific value of the gas delivered.
| Source | Factor | Unit |
|---|---|---|
| Natural gas | 0.18231 | kg CO₂e/kWh (gross calorific value) |
| Natural gas | 2.02633 | kg CO₂e/m³ |
| Diesel (100% mineral) | 2.66155 | kg CO₂e/L |
| Petrol (100% mineral) | 2.35372 | kg CO₂e/L |
| LPG | 1.55713 | kg CO₂e/L |
| Fuel oil | 3.17492 | kg CO₂e/L |
| Industrial coal | 2,415.04 | kg CO₂e/t |
| R-410A; R-32; R-134a; R-404A | 1,924; 677; 1,300; 3,943 | kg CO₂e/kg (GWP, AR5) |
| Türkiye electricity grid (Ember 2025) | 0.4758 | kg CO₂e/kWh |
| Well-to-tank: natural gas; diesel; petrol; LPG | 0.03021; 0.62409; 0.60664; 0.18551 | kg CO₂e/kWh or L |
| Average diesel car | 0.17265 | kg CO₂e/km |
| Flights: domestic; short-haul economy | 0.22928; 0.12576 | kg CO₂e/passenger-km |
The factors come from the UK DESNZ 2026 set (version 1.2, IPCC AR5 GWPs) and the grid value from Ember's 2025 data. The well-to-tank (WTT) factor covers extracting, refining and transporting the fuel and goes into Scope 3 category 3. Flight factors are DESNZ's UK values, used as proxies for Türkiye. They include the extra warming effect at altitude (radiative forcing). For comparison, Ember's 2025 grid intensities: Germany 0.3341, the Netherlands 0.2537, Russia 0.4469, the United Kingdom 0.2180, world average 0.4601 kg CO₂e/kWh.
Why is Scope 2 calculated two ways?
Electricity answers two separate questions: how much the grid you are connected to emits on average (the location-based method), and how your electricity contracts change that (the market-based method).
The GHG Protocol Scope 2 Guidance requires a company operating in any market with contractual instruments to report both results, each labelled by method. TSRS 2 requires disclosure of location-based Scope 2 and of the information on contractual instruments that users need.
In Türkiye, the local contractual instrument is the YEK-G certificate: each certificate corresponds to 1 MWh of renewable electricity generation and is issued by EPİAŞ, the energy exchange operator. International I-REC certificates serve the same purpose. In the market-based calculation, certified kWh are multiplied by zero. For uncertified kWh, the guidance calls for a residual mix factor that removes voluntary purchases. Since no residual mix factor is published for Türkiye, PureField's calculators multiply those kWh by the grid average. The guidance allows the grid average in that case; the report states that no residual mix is available and that this may cause double counting between consumers.
| Item | Location-based | Market-based |
|---|---|---|
| YEK-G certified 200,000 kWh | 200,000 × 0.4758 = 95.16 t | 0 t |
| Uncertified 300,000 kWh | 300,000 × 0.4758 = 142.74 t | 300,000 × 0.4758 = 142.74 t |
| Scope 2 total (500,000 kWh, 40% YEK-G) | 237.90 t | 142.74 t |
On a consumption of 500,000 kWh, every 10 points of YEK-G share lowers the market-based result by 23.79 t (50,000 kWh × 0.4758); the location-based result does not change. With all consumption certified, market-based Scope 2 is zero while location-based Scope 2 is still reported at 237.9 t.
The source of the grid factor also matters. Ember's 2025 value is a life-cycle intensity: it includes emissions from fuel production, the supply chain and building the power plants. The Scope 2 Guidance asks for combustion-only emission rates in Scope 2 and puts the upstream part in Scope 3 category 3. For official reporting, use the national authority's factor. In that case, electricity's upstream emissions go separately into Scope 3 category 3. The information form of Türkiye's Ministry of Energy and Natural Resources (2022 calculation period, published 6 December 2024) gives 0.478 t CO₂e/MWh for consumption points connected to the distribution grid and 0.445 for those connected to the transmission grid. The same 500,000 kWh at the distribution factor comes to 239.0 t, less than 0.5% away from the Ember result.
Example: a mid-sized manufacturing and service company
The company below is fictional; the figures were chosen to show how the calculation is built. Every line uses the factors above.
- A company with 95 employees that makes air conditioning and refrigeration equipment and services it; one factory and one office. Vehicles and buildings are under its operational control.
- Annual energy: 600,000 kWh of natural gas (heating and the paint oven), 500,000 kWh of electricity, 40% of it YEK-G certified.
- Vehicle fuel: 14 diesel service vans 42,000 L, 3 petrol pool cars 4,500 L, 2 LPG forklifts 3,000 L.
- Refrigerant top-ups in the company's own equipment: 8 kg R-410A in office air conditioners, 3 kg R-404A in a test chamber; 2 kg R-22 in an old unit.
- Business travel: 80 domestic flights averaging 700 km (56,000 passenger-km), 12 European flights averaging 2,000 km in economy (24,000 passenger-km), and 30,000 km in employees' cars (assumed average diesel cars).
- 4,800 service visits a year.
| Source | Scope | Activity data | Factor | t CO₂e | Share |
|---|---|---|---|---|---|
| Electricity, location-based | Scope 2 | 500,000 kWh | 0.4758 | 237.90 | 41.7% |
| Diesel, service vans | Scope 1 | 42,000 L | 2.66155 | 111.79 | 19.6% |
| Natural gas | Scope 1 | 600,000 kWh | 0.18231 | 109.39 | 19.2% |
| Well-to-tank emissions of fuels | Scope 3, category 3 | Four fuels | By fuel | 47.62 | 8.4% |
| R-410A top-up | Scope 1 | 8 kg | 1,924 | 15.39 | 2.7% |
| Domestic flights | Scope 3, category 6 | 56,000 passenger-km | 0.22928 | 12.84 | 2.3% |
| R-404A top-up | Scope 1 | 3 kg | 3,943 | 11.83 | 2.1% |
| Petrol, pool cars | Scope 1 | 4,500 L | 2.35372 | 10.59 | 1.9% |
| Business travel by car | Scope 3, category 6 | 30,000 km | 0.17265 | 5.18 | 0.9% |
| LPG, forklifts | Scope 1 | 3,000 L | 1.55713 | 4.67 | 0.8% |
| European flights, economy | Scope 3, category 6 | 24,000 passenger-km | 0.12576 | 3.02 | 0.5% |
| Total, location-based | – | – | – | 570.22 | 100% |
The well-to-tank line breaks down as natural gas 18.13 t, diesel 26.21 t, petrol 2.73 t and LPG 0.56 t. Because the Ember factor already includes the upstream part, there is no separate well-to-tank line for electricity, so the same emissions are not counted twice. Shares are rounded. The R-22 top-up (2 kg × 1,760 = 3.52 t CO₂e) is a Montreal gas, so it stays out of the total and is shown on a separate line of the report.
| Scope | Location-based | Market-based, 40% YEK-G |
|---|---|---|
| Scope 1 | 263.66 t (46.2%) | 263.66 t (55.5%) |
| Scope 2 | 237.90 t (41.7%) | 142.74 t (30.0%) |
| Scope 3, categories in the example | 68.66 t (12.0%) | 68.66 t (14.5%) |
| Total | 570.22 t | 475.06 t |
The same result in ISO 14064-1 categories:
| ISO 14064-1 category | Items in the example | t CO₂e |
|---|---|---|
| 1. Direct emissions | Fuels and refrigerant | 263.66 |
| 2. Imported energy | Electricity, location-based | 237.90 |
| 3. Transportation | Flights and business travel by car | 21.04 |
| 4. Products used by the organization | Well-to-tank emissions of fuels | 47.62 |
The three largest sources (electricity, the service fleet's diesel and natural gas) make up 80.5% of the total, so a reduction plan starts with those three lines. Intensity metrics allow comparison across periods and companies: 6.0 t CO₂e per employee (5.0 t market-based) and, for the fleet's diesel, 111,785 kg / 4,800 = 23.3 kg CO₂e per service visit.
The figure for the buyer comes from the same table. The Scope 3 Standard describes allocating a supplier's emissions by the customer's share of purchases, measured by mass, units or market value. The example company's Scope 1 and 2 total 501.56 t location-based and 406.40 t market-based. Service-fleet diesel (111.79 t) stays out of a product buyer's share: 389.77 / 294.61 t (location/market); a customer taking 10% of product sales gets 39.0 / 29.5 t.
The example leaves out purchased materials (category 1), freight (4), waste (5), employee commuting (7) and use of sold products (11); those need spend, weight or product data. For a manufacturer that sells air conditioners, category 11 covers the electricity the units use over their lifetime and the refrigerant that leaks during use. The total grows as those categories are added; the 570 tonnes are the Scope 1, Scope 2 and partial Scope 3 part of the inventory.
What changes when the records are digital?
The formula is simple; the hard part is collecting the right activity data every month, together with its source. For the example company, that means 12 gas and 12 electricity invoices, fuel card statements for 17 vehicles and 4,800 service reports a year. Four things change once these records are digital:
- Refrigerant becomes visible per unit: With a "refrigerant top-up (kg)" measurement defined in the service report, every top-up builds up in the unit's reports, and repeated top-ups show on the chart drawn from those reports. A single unit that loses 1.5 kg of R-410A every quarter comes to 6 kg × 1,924 = 11.54 t CO₂e a year. That is about 10% of the annual diesel emissions of the example company's 14-van fleet, the equivalent of 4,337 litres of diesel. The gas type should be recorded too: 1 kg of R-410A is 1,924 kg CO₂e, 1 kg of R-32 is 677. Because the unit belongs to the customer, this is the customer's Scope 1; the measured quantity in the service report becomes data for the customer's own inventory.
- Travel emissions split by job and customer: The fuel card gives the fleet's total litres; you split that total across visits by the distance in each service report. With the average diesel car factor (a proxy for vans), an 80 km round trip is 13.8 kg CO₂e, or 165.7 kg a year for a customer with 12 visits. A 120 km repeat visit is 20.7 kg CO₂e; 100 repeat visits a year come to 2.07 tonnes.
- The customer has its data after every visit: The saved report's PDF is emailed automatically, with top-up kilograms in its measurement table.
- The uncertainty assessment narrows: ISO 14064-1 requires uncertainty to be assessed at category level. As measured data such as invoices, meter readings and service forms replace estimates derived from spend, the range of that assessment shrinks.
Most of these records come out of the work itself: service reports, maintenance plans, invoices, purchase orders. You enter the annual totals in the calculator; service reports, invoices and fuel card statements are the source of those totals.
Who has to report in Türkiye?
Three sets of rules create direct obligations in Türkiye: the TSRS scope decision of KGK (the Public Oversight, Accounting and Auditing Standards Authority), the Emissions Trading System under the Climate Law, and the EU's Carbon Border Adjustment Mechanism (CBAM) for exports.
TSRS is mandatory for certain entities regulated under capital markets, banking and insurance law, such as listed companies, banks and insurers. Among them, those that exceed at least two of three thresholds in two consecutive periods are in scope: total assets of TRY 1 billion, annual net sales of TRY 2 billion and 500 employees. The thresholds were updated in January 2026 for accounting periods starting on or after 1 January 2025; banks other than those under the Savings Deposit Insurance Fund are in scope regardless of thresholds. Companies outside the scope may apply TSRS voluntarily.
TSRS 2 requires Scope 1, 2 and 3 to be disclosed in tonnes of CO₂e; KGK's scope decision grants Scope 3 relief for the first two annual periods. Because Scope 3 includes purchased goods and services, a supplier that is not in scope itself may still receive data requests.
Climate Law No. 7552 was published on 9 July 2025 and provides for an Emissions Trading System (ETS). The ETS Regulation published on 27 August 2026 covers installations carrying out the activities in its Annex 1 with annual emissions above 50,000 t CO₂e; they submit a verified emissions report by 30 April each year. The system starts with a pilot period whose scope and duration are set by the Carbon Market Board. The law also allows for a national carbon border adjustment mechanism.
The EU's CBAM entered its definitive period on 1 January 2026. It covers imports of iron and steel, aluminium, cement, fertilisers, hydrogen and electricity; the list goes beyond raw materials and includes iron and steel articles such as screws and bolts. For goods other than hydrogen and electricity, no obligation arises if an importer's total annual imports stay below 50 tonnes net mass. The declaration for 2026 imports is due by 30 September 2027, and sales of CBAM certificates start on 1 February 2027. Free allocation to EU producers in these sectors falls to 97.5% in 2026 and 51.5% in 2030 and ends in 2034, so the share the importer pays grows accordingly.
The EU importer asks the installation that produced the goods for actual embedded emissions: the figure the installation calculates under the EU method and an accredited CBAM verifier confirms. The Commission publishes a communication template for this exchange, and the first verification reports are expected in early 2027. If the installation does not provide the data, the importer uses default values.
How do you calculate a carbon footprint in PureField?
PureField is business management software that runs on AI agents and keeps sales, service, purchasing and finance records on one platform. The Tools section in the panel's side menu has a corporate carbon footprint calculator that works to the GHG Protocol and ISO 14064-1:
- Scope 1 and Scope 2; location-based and market-based Scope 2, with YEK-G or I-REC certified consumption.
- Scope 3 materials, well-to-tank emissions of fuels, freight, waste, business travel, employee commuting and water.
- A choice of AR5 or AR6 GWPs, uncertainty by data quality, an ISO 14064-1 category table, a breakdown by gas and intensity metrics.
- Reduction notes for the three largest sources.
The same menu also has water footprint, energy and greenhouse gas conversion, SBTi target path, product carbon footprint and CBAM embedded emissions calculations. The tools are open to all staff in the web panel, in the customer portal and in the mobile app (version 1.4.9, on the App Store and Google Play). One engine runs every calculation on the server, so web, portal and mobile show the same result. Every calculation is saved to history: give it a title and it becomes a saved calculation that you can reopen, edit and recalculate. The base year and the years after it stay as separate records.
The free carbon footprint calculator on this site uses the same factors and formulas. It covers Scope 1 (fuels, vehicle fuel, refrigerant top-ups), both Scope 2 methods and part of Scope 3 (well-to-tank emissions of fuels, business flights and car travel); every item in the example above falls within that coverage. Materials, freight, waste, commuting, uncertainty, the ISO 14064-1 table and saved history are in the panel. To account for water, see the water footprint guide.
Part of the activity data is created in the PureField field service module; you enter the annual totals in the calculator. The mobile service report records travel (office to customer to office, distance, crew, breaks) and service duration. Measurement values your company defines, such as refrigerant top-up kilograms, print in the service report PDF as a table and as a line chart drawn from the asset's recent reports. As an asset's next maintenance date approaches, the customer gets a reminder email. The QR asset card shows the unit's history in one place. Plans and prices are on the pricing page.
If you need a verified greenhouse gas statement, this calculation is the preparation of the data set that goes to the verifier.
Evidence
- GHG Protocol Corporate Standard (revised edition)
- Definitions of Scope 1, 2 and 3, the requirement to report Scope 1 and 2 separately and Scope 3 as optional (Chapter 4), reporting non-Kyoto gases separately from the scopes (Chapters 4 and 9), consolidation approaches (Chapter 3). Source: ghgprotocol.org
- GHG Protocol Scope 2 Guidance (2015)
- Dual reporting (section 1.5.1), location-based and market-based factor hierarchies and combustion-only emission rates (Tables 6.2 and 6.3), grid average and the disclosure duty when no residual mix exists (Chapter 6 and Table 7.1), upstream life-cycle emissions in Scope 3 category 3. Source: ghgprotocol.org
- GHG Protocol Scope 3 Standard and Scope 3 technical guidance
- 15 categories (Table 5.3), direct use-phase emissions in category 11 including refrigeration and air conditioning equipment, allocating supplier emissions (Chapter 8), supplier-specific and hybrid methods for category 1. Source: ghgprotocol.org, ghgprotocol.org
- ISO 14064-1 (2018 edition)
- Six inventory categories (clause 5.2.4), direct emissions by gas (5.2.2), selecting significant indirect emissions (5.2.3), uncertainty assessment (8.3), category contents and the leased fleet example (Annex B). Source: iso.org
- UK DESNZ greenhouse gas conversion factors 2026 (version 1.2)
- The fuel, well-to-tank, refrigerant, car and flight factors in this article; GWPs from IPCC AR5, 100 years; calculating leaks from top-ups and the Montreal Protocol row for R-22 (Refrigerant & other sheet). Source: gov.uk
- Ember yearly electricity data
- 2025 grid intensities (Türkiye 475.8, Germany 334.1, Netherlands 253.7, Russia 446.9, United Kingdom 218.0, world 460.1 g CO₂e/kWh) and the life-cycle emissions method. Source: ember-energy.org, ember-energy.org
- Türkiye Ministry of Energy and Natural Resources emission factor information form (2022 calculation period)
- Consumption-point factors of 0.478 (distribution) and 0.445 (transmission) t CO₂e/MWh, with the note that they can be used in carbon footprint calculations. Source: enerji.gov.tr
- Regulation on Renewable Energy Source Guarantee Certificates in the Electricity Market (Official Gazette 14 November 2020, No. 31304)
- One YEK-G certificate per 1 MWh of generation, EPİAŞ as issuing body, in force from 1 June 2021. Source: resmigazete.gov.tr
- Natural Gas Market Tariffs Regulation, Article 18
- The billed energy quantity is found in kWh by multiplying the gross calorific value by the volume in Sm³. Source: mevzuat.gov.tr
- KGK decision on the scope of TSRS (Official Gazette 29 December 2023, No. 32414 bis) and threshold update (Official Gazette 16 January 2026, No. 33139)
- Entities in scope, two of three thresholds in two consecutive periods, thresholds of TRY 1 billion, TRY 2 billion and 500 employees (from 1 January 2025), Scope 3 relief in the first two years (transitional article 3). Source: resmigazete.gov.tr, resmigazete.gov.tr
- TSRS 2 Climate-related Disclosures
- Scope 1, 2 and 3 disclosed in t CO₂e, measurement under the GHG Protocol Corporate Standard, location-based Scope 2 and contractual instruments (paragraph 29(a), B30 and B31). Source: kgk.gov.tr
- Climate Law No. 7552 (Official Gazette 9 July 2025, No. 32951)
- Establishing the ETS (Article 9), a possible national carbon border mechanism (Article 8), pilot period (provisional Article 1). Source: resmigazete.gov.tr
- Türkiye Emissions Trading System Regulation (Official Gazette 27 August 2026, No. 33353)
- Category B and C installations above 50,000 t CO₂e a year (Articles 4 and 5), verified emissions report by 30 April (Articles 29 and 30), pilot period (provisional Article 1). Source: resmigazete.gov.tr
- European Commission CBAM questions and answers (15 October 2026) and Guidance Document 4 (14 August 2026)
- Definitive period from 1 January 2026, sectors covered, the 50-tonne threshold, the 30 September 2027 declaration, certificate sales from 1 February 2027, actual verified embedded emissions from the producer, the communication template, the CBAM factor table (2026 97.5%, 2030 51.5%, 2034 0%), screws and bolts (CN 7318) in scope. Source: taxation-customs.ec.europa.eu, taxation-customs.ec.europa.eu
- European Commission Access2Markets notice (28 January 2026)
- The 50-tonne threshold applies to each importer's total net mass per calendar year and not to hydrogen and electricity. Source: trade.ec.europa.eu
- PureField Tools
- Corporate carbon footprint calculator (GHG Protocol and ISO 14064-1, Scope 1, 2 and 3, AR5 or AR6, uncertainty, ISO 14064-1 table, gas breakdown, intensity metrics, reduction notes), water footprint, energy and greenhouse gas conversion, SBTi target path, product carbon footprint and CBAM embedded emissions; web panel, customer portal and mobile app 1.4.9; one server-side engine and saved calculations. The free calculator on this site uses the same factors and formulas.
- Mobile service report
- Travel (office to customer to office, distance, crew, breaks) and service duration go into the report; measurement values the company defines print in the PDF as a table and a line chart drawn from the asset's recent reports; when the report is saved, an email with the PDF goes to the customer.
Take the last 12 months of gas, electricity and fuel invoices and get your first Scope 1 and 2 result in the free calculator. Book a demo or try it free for 7 days.
Frequently asked questions
Is calculating a carbon footprint mandatory?
Do we have to calculate Scope 3?
Does a YEK-G certificate bring Scope 2 to zero?
Whose emissions is the refrigerant we put into a customer's air conditioner?
Do the free calculator and the PureField panel give the same result?
Related links
- Free carbon footprint calculatorScope 1, both Scope 2 methods and part of Scope 3, with the same factors.
- How to calculate a company's water footprintBlue water with harvested rainwater, grey water, and how to measure a company's water use.
- PureField field serviceMobile service report, measurement values and QR asset card.
- HVAC service softwareWork orders, device cards and maintenance tracking.
- Air compressor maintenance trackingMeasurements, the leak test and maintenance records.
- Periodic maintenance tracking programMaintenance calendar and reminders.
- What is business management software?Sales, service, purchasing and finance working from the same records.
