Guide, Platform
How to calculate a company's water footprint: blue and grey water
- Author
- PureField
- Published
- Updated
A company's water footprint is calculated from one year's balance of the water it withdraws, returns and consumes. Blue water is the part of freshwater withdrawals, harvested rainwater included, that does not return to the same catchment; grey water is the volume needed to dilute the pollution load in the discharge. The AWARE factor used under ISO 14046 weights blue consumption by local water scarcity. Green water, the third colour, is rainfall that plants take up from the soil and belongs to the footprint of crops.
What does a water footprint measure?
A water footprint shows, in cubic meters, how much freshwater is consumed and how much is polluted. The Water Footprint Assessment Manual of the Water Footprint Network (WFN) defines three components:
- Blue water footprint: Consumption of surface water and groundwater. Rainwater harvested from roofs and paved surfaces also counts here.
- Green water footprint: Consumption of rainwater stored in the soil and used by plants, the part that does not become run-off. It is calculated for crop and forestry products; a site's direct water footprint is made up of blue and grey water.
- Grey water footprint: The volume of freshwater needed to assimilate a pollutant load, given the natural background concentration and the ambient water quality standard of the receiving water.
The key word is consumption. Under the manual, water counts as consumed in four cases: it evaporates, it is incorporated into a product, it does not return to the same catchment (it goes to another catchment or the sea), or it does not return in the same period. Well water that you treat and release to a stream goes in the withdrawal column; only the part that does not return to the stream counts as consumption.
The manual defines the water footprint as a volumetric measure and stresses that local impact depends on how vulnerable the local water system is. ISO 14046:2014 assesses the potential environmental impacts related to water. The standard is based on life cycle assessment; an assessment can stand alone or be part of a broader environmental assessment, and its result is a single value or a profile of impact indicator results. The calculation in this guide measures direct water use within the site boundary. A full ISO 14046 assessment that also covers the supply chain is a separate study.
How do you separate withdrawal, discharge and consumption?
The calculation starts with an annual water balance: how much water came from each source, and how much went where. The difference is consumption.
| Item | Example | Where it goes in the calculation |
|---|---|---|
| Freshwater withdrawal | Mains, industrial zone network, well, stream or lake | Source of blue water |
| Harvested rainwater | Rain collected from roofs and paved surfaces and stored | Source of blue water |
| Recycled water from outside | Treated water from another site | Counts in total withdrawal; blue water comes from freshwater and rainwater only |
| Discharge to the sewer or a treatment plant | Municipal or industrial zone wastewater network | Returned if the plant's outlet reaches the same catchment, consumption if the sea |
| Discharge to receiving water | Treated effluent released to a stream | Returned |
| Water supplied to a third party | Water passed to a neighboring site for its own use | Returned |
| Discharge to the sea | Sea outfall of a coastal site | Consumption |
Two equations set up the balance:
Consumption = total withdrawal − returned water
Retained share = 1 − returned water ÷ total withdrawal
Total withdrawal includes freshwater, rainwater and recycled water from outside. Consumption includes evaporation in cooling towers, steam losses, water incorporated into products and leaks that no meter catches. Water discharged to the sea does not return to the freshwater catchment it came from, so it counts as consumption.
Closing the balance is the first check. If consumption comes out below zero, either a meter is wrong or rainwater is getting into the wastewater line. If it is higher than expected, look for leaks first.
How do you calculate blue water?
Blue water is the retained share of freshwater withdrawals. The WFN manual (p. 26) also counts consumption of rainwater harvested from roofs and paved surfaces as blue, so harvested rainwater is added to freshwater withdrawals.
Blue water = (freshwater withdrawal + harvested rainwater) × retained share
The formula spreads consumption across sources in proportion to withdrawal. If you consume a quarter of the water you withdraw, a quarter of the well water and a quarter of the rainwater count as consumed. The share of recycled water from outside stays in consumption; blue water is calculated from freshwater and rainwater.
PureField's calculator also adds harvested rainwater to blue water. The part of blue water that came from rainwater appears on its own information line and is not added to the total a second time. The scarcity footprint is calculated from blue water, rainwater included.
Roof area and rainfall set how much rainwater you can collect. According to DSİ, Türkiye's State Hydraulic Works, average annual rainfall in Türkiye is about 574 mm. Assuming 80% of the rain is captured, a 9,000 m² roof yields 9,000 × 0.574 × 0.8 = about 4,133 m³ a year. Run the numbers with the rainfall figure for your own province.
Two more indicators complete the picture:
- Intensity per unit: Divide the totals by production (m³ per tonne). The manual also expresses a product's water footprint as volume per unit of product.
- Recycling rate: Water reused on site ÷ (water reused + water withdrawn).
How do you calculate grey water?
Grey water is the volume of water needed to bring the pollutant load in your discharge down to a concentration the receiving water can take. First the load, then the grey water:
Load (L) = discharge volume × effluent concentration − withdrawal × intake concentration
Grey water = L ÷ (c_max − c_nat)
With volume in m³ and concentration in mg/L, the load comes out in grams, since 1 mg/L = 1 g/m³. If the intake water already carries the pollutant, its load is subtracted: withdrawing 64,000 m³ at an average of 0.5 mg/L nitrogen takes 32 kg off the load. A load below zero counts as zero.
- c_max: The ambient water quality standard of the receiving water, the highest concentration accepted in that water body. The limit in your discharge permit applies to the effluent itself; the grey water calculation uses the standard for the receiving water.
- c_nat: The natural concentration the water body would have without human influence. If unknown, it can be set to 0; according to the manual, this understates grey water.
For inland surface waters in Türkiye, c_max can be taken from Annex 5, Table 2 of the Surface Water Quality Regulation (Yerüstü Su Kalitesi Yönetmeliği), as amended in 2021:
| Parameter | Class I (very good) | Class II (good) |
|---|---|---|
| COD (mg/L) | < 25 | 50 |
| Total nitrogen (mg N/L) | < 3.5 | 11.5 |
| Total phosphorus (mg P/L) | < 0.08 | 0.2 |
State in the report which class you used; the manual asks for the standards and natural concentrations used to be named explicitly.
If you measure more than one pollutant, calculate grey water for each. The pollutant with the largest result is the critical pollutant, and its value is the site's grey water footprint. Example: 10,000 m³ of wastewater is discharged at 120 mg/L COD, with c_max 25 mg/L and c_nat 0. The load is 10,000 × 120 = 1,200,000 g, or 1,200 kg; grey water is 1,200,000 ÷ 25 = 48,000 m³.
If your wastewater goes to an industrial zone or municipal treatment plant: the manual calculates grey water from the quality of the effluent as it is finally released to the environment. If you can get the plant's outlet values, use them; a calculation with your own discharge values gives a higher, conservative result.
How do you find the water scarcity footprint with AWARE?
The same cubic meter puts more pressure on a dry basin than on a wet one. AWARE accounts for this with a multiplier. The WULCA working group developed the method, and the UNEP-SETAC Life Cycle Initiative and the European Commission's PEF/OEF program recommend it.
Scarcity footprint = blue consumption × AWARE factor (m³ world equivalent)
AWARE compares the water remaining per unit area in a basin, after the demand of people and aquatic life is met, with the world average. The factor runs from 0.1 to 100: 1 is the world average, and 10 means ten times less water remaining per unit area than the world average. Türkiye's annual country factor for non-agricultural use is 22.24. One cubic meter consumed in Türkiye carries the same scarcity impact as about 22 m³ consumed in a region where the water remaining equals the world average.
| Country or region | Non-agricultural AWARE factor | Scarcity footprint of 16,000 m³ blue consumption (m³ world eq.) |
|---|---|---|
| Türkiye | 22.24 | 355,840 |
| Russia | 3.66 | 58,560 |
| Germany | 1.12 | 17,920 |
| Netherlands | 0.96 | 15,360 |
| World average (location unknown) | 20.30 | 324,800 |
Türkiye's agricultural factor is 58.04, and 56.46 applies when the type of use is unspecified. The 20.30 used when the location is unknown is WULCA's consumption-weighted world average; it differs from the 1 used for normalization.
The country average is a starting point. In the same WULCA file, Türkiye's monthly non-agricultural factor is about 2 in January and about 49 in July, and the file's variability table gives basin resolution priority for Türkiye. Basin- and month-level factors give a more accurate result; for that, you need to know in which basin and in which month the water is consumed.
How do you calculate a site's water footprint, step by step?
The site below is fictional, and every value is an assumption. A dairy plant processes 20,000 tonnes of milk a year. It reuses part of its treated wastewater for cooling tower make-up and yard washing and releases the rest to a stream.
| Item | Annual value |
|---|---|
| Mains water | 16,000 m³ |
| Well water | 44,000 m³ |
| Harvested rainwater | 4,000 m³ |
| Treated effluent released to the stream | 48,000 m³ |
| Treated water reused on site | 16,000 m³ |
| AWARE factor (Türkiye, non-agricultural) | 22.24 |
| Parameter | Effluent concentration | Intake concentration | c_max (Class I) | c_nat |
|---|---|---|---|---|
| COD | 60 mg/L | 0 | 25 mg/L | 0 |
| Total nitrogen | 11 mg/L | 0 | 3.5 mg/L | 0.5 mg/L |
COD and nitrogen were not measured in the intake water, so the intake concentration is set to 0; this conservative assumption makes the load larger. The natural COD concentration is also unknown; setting it to 0 makes grey water slightly smaller.
The calculation takes ten steps:
- Total withdrawal = 16,000 + 44,000 + 4,000 = 64,000 m³
- Consumption = 64,000 − 48,000 = 16,000 m³; retained share = 1 − 48,000 ÷ 64,000 = 0.25
- Blue water = (16,000 + 44,000 + 4,000) × 0.25 = 16,000 m³
- Rainwater part of blue water = 4,000 × 0.25 = 1,000 m³ (an information line, not added to the total again)
- COD load = 48,000 × 60 − 64,000 × 0 = 2,880,000 g (2,880 kg); grey water = 2,880,000 ÷ 25 = 115,200 m³
- Nitrogen load = 48,000 × 11 − 64,000 × 0 = 528,000 g (528 kg); grey water = 528,000 ÷ (3.5 − 0.5) = 176,000 m³
- The critical pollutant is total nitrogen; grey water footprint = 176,000 m³
- Total water footprint = blue + grey = 16,000 + 176,000 = 192,000 m³
- Scarcity footprint = 16,000 × 22.24 = 355,840 m³ world equivalent
- Recycling rate = 16,000 ÷ (16,000 + 64,000) = 20%
| Indicator | Annual | Per tonne of milk |
|---|---|---|
| Withdrawal | 64,000 m³ | 3.2 m³ |
| Consumption | 16,000 m³ | 0.8 m³ |
| Blue water | 16,000 m³ | 0.8 m³ |
| Harvested rainwater (included in blue) | 1,000 m³ | 0.05 m³ |
| Grey water | 176,000 m³ | 8.8 m³ |
| Total water footprint | 192,000 m³ | 9.6 m³ |
| Scarcity footprint | 355,840 m³ world eq. | 17.79 m³ world eq. |
The nitrogen load is less than a fifth of the COD load (528 kg against 2,880 kg), yet its grey water is larger, because the receiving water tolerates far less nitrogen. Grey water makes up 92% of the total footprint; this site's largest water item is the quality of its effluent. The choice of c_max drives the result: with Class II limits (COD 50, total nitrogen 11.5 mg/L), the same loads give 57,600 and 48,000 m³ of grey water, the critical pollutant switches to COD and the total footprint drops to 73,600 m³.
The calculator uses the unrounded AWARE factor (Türkiye non-agricultural 22.2409), so the same data gives a scarcity footprint of 355,854.4 m³ instead of 355,840. You can run the same steps with your own data in the free water footprint calculator.
What do Türkiye's water efficiency rules require?
According to DSİ, Türkiye is among the countries under water stress when measured by usable water per person. Its consumable surface water and groundwater potential averages 112 billion m³ a year, of which 57 billion m³ is used: 44 billion m³ for irrigation and 13 billion m³ for drinking water and industry. Usable water per person fell from 1,652 m³ in 2000 to 1,346 m³ in 2020. Presidential Circular No. 2023/9 states that, according to climate change projections, water resources are expected to decline by about 25% over the next hundred years. The circular announces the Water Efficiency Strategy Document and Action Plan (2023–2033), prepared under the national Water Efficiency Mobilization.
For industry, the binding rule is the Water Efficiency Regulation (Su Verimliliği Yönetmeliği), published in the Official Gazette on 27 December 2024, issue 32765:
- Scope: Facilities operating under one of the 148 NACE codes in Annex 2 with 50 or more employees, as well as organized industrial zones, free zones and industrial zones, set up a water efficiency system within 18 months of publication; that period ended on 27 June 2026. The list covers activities such as food, beverage, textile, paper, chemical, plastics, metal and machinery manufacturing.
- System: Assigned staff, a water efficiency plan, training, and implementing, monitoring and reporting the plan. The plan covers current and planned water use, targets and measures. It goes into the Ministry's information system with its five-year schedule for approval, and results are monitored and entered every year.
- Measurement: One of the regulation's general principles is that water use is recorded through measurement and monitoring systems.
- Certificates: The water efficiency certificate has three levels, blue, green and turquoise, each valid for five years. An obligated party that sets up the system receives the blue certificate. Annex 2 activities apply for the green certificate within five years at most; with the Ministry's approval, this period can be extended to seven years.
- Green certificate: For NACE activities, 10% of total water use comes from non-conventional sources such as wastewater, rainwater, greywater (lightly used wash water), brackish water or seawater, and the techniques in the guidance document for the NACE code are applied. TS ISO 46001 certification is required at renewal.
- Turquoise certificate: Voluntary. For NACE activities, at least 20% of wastewater is recovered and reused; certification under TS ISO 46001 and TS EN ISO 14046 is also among the criteria.
Water users without the obligation also report the water use data the Ministry requests, in the format it sets. In short, the data the rules ask for is the data a water footprint relies on: water use by source, wastewater and reuse volumes, and annual monitoring. This section summarizes the regulation; confirm your site's scope and schedule against the Ministry's guidance documents.
What changes when the records go digital?
How accurate a water footprint is depends more on the data than on the formula: a meter read once a year, a lab result that stays on paper, a leak nobody notices. The figures below are scenarios calculated for the example site above, each with its assumption stated.
How long does a leak run? A 0.5 m³/h leak draws 12 m³ a day and 360 m³ in 30 days. The leaked water bypasses the discharge meter, so the balance shows it as consumption. Assume the leak is caught at the first meter reading after it starts:
| Meter reading frequency | Leak duration | Extra water withdrawn | Scarcity footprint (leaked volume × 22.24) |
|---|---|---|---|
| Once a year (leak starts on 1 February, read on 31 December) | 334 days | 4,008 m³ | 89,138 m³ world eq. |
| Monthly | Up to 30 days | 360 m³ | 8,006 m³ world eq. |
| Weekly | Up to 7 days | 84 m³ | 1,868 m³ world eq. |
With yearly readings, the same leak raises the example site's consumption by 25%, from 16,000 to 20,008 m³. Reading the meter twice while production is stopped also reveals a leak: a 4 m³ difference over 8 hours means a flow of 0.5 m³/h.
What does reuse change? Say the example site raises reuse from 16,000 to 24,000 m³. Total water use (80,000 m³), consumption and effluent concentrations (the plant holds its outlet concentration) stay the same, and the lower withdrawal comes from the well.
| Indicator | Today | Reuse at 24,000 m³ |
|---|---|---|
| Withdrawal | 64,000 m³ | 56,000 m³ |
| Discharge | 48,000 m³ | 40,000 m³ |
| Consumption | 16,000 m³ | 16,000 m³ |
| Recycling rate | 20% | 30% |
| Blue water | 16,000 m³ | 16,000 m³ |
| Grey water (total nitrogen) | 176,000 m³ | 146,667 m³ |
| Scarcity footprint | 355,840 m³ | 355,840 m³ |
Withdrawal falls by 12.5% and grey water by about 17%. Blue water and the scarcity footprint stay where they are, because they measure consumption. They come down through measures that cut consumption: less evaporation in cooling towers, lower steam losses, fewer leaks.
What does monthly data show? Türkiye's non-agricultural AWARE factor is about 2 in January and about 49 in July. Higher cooling water consumption in summer carries a larger scarcity impact than the annual average suggests. Monthly meter readings show which months consumption is concentrated in. Five meters (mains, well, rainwater tank, discharge, reuse) read monthly give 60 readings a year, and two effluent parameters measured monthly give 24 lab results; the annual calculation comes from these 84 values.
For water treatment service companies: Reading the feed and product water meters of a reverse osmosis (RO) unit at every monthly visit lets you track its recovery rate (product water ÷ feed water) from report to report. If a unit producing 2 m³ of product water a day drops from 75% to 60% recovery, feed water rises from 2.67 to 3.33 m³ a day: about 20 m³ more withdrawal a month and about 243 m³ a year. If the concentrate goes to the sewer, the increase shows up in the customer's withdrawal and discharge rather than its consumption.
How do you calculate a water footprint in PureField?
The Tools section in the side menu of the PureField web panel includes a water footprint calculation: blue and grey water on the Water Footprint Network method with harvested rainwater counted as blue, the ISO 14046 AWARE scarcity footprint, the water balance and the critical pollutant. The formulas and factors in this guide are the ones the calculation uses.
- Who uses it: Tools is open to all staff in the web panel. It is also in the customer portal and the mobile app (version 1.4.9, in both app stores); staff open it from their apps menu, customer accounts from the main menu.
- Same number: The calculation runs on the server in a single engine, so web, portal and mobile show the same result.
- History: Every calculation is saved to history. Give it a title and a description to make it a saved calculation; next year, open it, edit the values and recalculate.
- Carbon calculations: The same section has a corporate carbon footprint, an energy and greenhouse gas converter, an SBTi target path, a product carbon footprint and CBAM embedded emissions. We cover the carbon side in the corporate carbon footprint guide.
- Measurement records: In PureField field service, the measurement values your company defines, such as monthly meter readings, conductivity and hardness, go into the mobile service report. The service report PDF prints them as a table and as a chart drawn from the asset's last 20 reports; with monthly readings, that is a trend of about 20 months. You enter the annual totals into the water footprint calculation.
- Asset card and reminder: Meters and treatment units are set up as QR-coded asset cards, and the asset history builds up on the card. As an asset's next maintenance date approaches, the customer gets a reminder email.
The free water footprint calculator on this site uses the same factors and formulas: withdrawals, discharges, effluent parameters, AWARE by country and type of use, on-site reuse and intensity per unit. Saving calculations and reopening them from history happens in the panel. For companies that sell and service water treatment units, see water treatment; plans are on the pricing page.
Evidence
- Water Footprint Assessment Manual (WFN, 2011)
- Definitions of blue, green and grey water (p. 2), volumetric measure versus local impact (p. 3), volume per unit of product (p. 23), the four cases of consumptive use (pp. 24–25), rainwater harvested from roofs and paved surfaces counted as blue water (p. 26), the grey water formula, c_max, c_nat and naming the standards used (pp. 30–32), point-source load, negative loads set to zero and the effluent as finally released (pp. 34–35), critical pollutant (p. 39). Source: waterfootprint.org, copy: ayhoekstra.nl
- Grey water footprint Tier 1 guidelines (UNESCO-IHE, 2013)
- A separate calculation per pollutant with the largest result taken, the point-source load formula, ambient water quality standards and natural concentrations (pp. 11–13); EU, US-EPA or CCME values where no local standard exists (p. 29). Source: waterfootprint.org, copy: ayhoekstra.nl
- ISO 14046 (2014)
- Principles, requirements and guidelines for water footprint assessment; based on life cycle assessment, can stand alone or be part of a broader assessment, and the result is a single value or a profile of impact indicator results. Source: iso.org
- WULCA AWARE method
- Indicator of water remaining per unit area, the 0.1–100 range, the meaning of 1 and 10, the consumption-weighted world average for unknown locations, and the UNEP-SETAC and PEF/OEF recommendations. Source: wulca-waterlca.org; method paper: Int J Life Cycle Assess 23, 2018
- AWARE country factors (version 1.2)
- Annual factors for Türkiye non-agricultural 22.24, agricultural 58.04, unspecified 56.46; Germany 1.12; Netherlands 0.96; Russia 3.66; world non-agricultural 20.30. Türkiye's monthly non-agricultural values and the variability table are in the same file. Source: wulca-waterlca.org
- Water Efficiency Regulation, Türkiye (Official Gazette, 27 December 2024, No. 32765)
- General principles including measurement and monitoring (Article 4), system stages (Article 5), plan content, five-year schedule and annual monitoring (Article 6), certificate levels and validity (Articles 7 and 9), data reporting (Provisional Article 1); obligated parties and the 18-month deadline (Annex 1), NACE list (Annex 2), green and turquoise certificate criteria (Annexes 4 and 5). Source: resmigazete.gov.tr, annexes: resmigazete.gov.tr
- Presidential Circular No. 2023/9, Türkiye (Official Gazette, 4 May 2023, No. 32180)
- Water Efficiency Strategy Document and Action Plan (2023–2033); a decline of about 25% in water resources expected over the next hundred years. Source: resmigazete.gov.tr
- DSİ soil and water resources
- Average annual rainfall of about 574 mm, consumable potential of 112 billion m³, 57 billion m³ used (44 irrigation, 13 drinking water and industry), usable water per person of 1,346 m³ in 2020, water stress. Source: dsi.gov.tr
- Surface Water Quality Regulation, Annex 5 Table 2, Türkiye (Official Gazette, 16 June 2021, No. 31513)
- Quality class limits for inland surface waters; COD Class I < 25 and Class II 50 mg/L, total nitrogen < 3.5 and 11.5 mg N/L, total phosphorus < 0.08 and 0.2 mg P/L. Source: resmigazete.gov.tr
- PureField Tools
- The water footprint calculation is open to all staff in the web panel, in the customer portal and in the mobile app (1.4.9); it runs on the server in a single engine, counts harvested rainwater as blue water and is saved to history. The free calculator on this site uses the same factors and formulas.
- Measurement analysis chart
- Measurement values defined for the mobile service report print in the PDF as a table and a line chart drawn from the asset's recent reports.
Save your first PureField water footprint calculation from the last 12 months' meter totals and effluent results. Book a demo or try it free for 7 days.
Frequently asked questions
What is the difference between water withdrawal, water consumption and water footprint?
Which limit value is used in a grey water calculation?
How does water sent to the sewer or the sea count?
Which AWARE factor applies to Türkiye?
Which facilities does Türkiye's Water Efficiency Regulation cover?
Related links
- Water footprint calculatorFree calculation from withdrawals, discharges and effluent values.
- How to calculate your corporate carbon footprintA company's greenhouse gas inventory, step by step.
- PureField field serviceQR asset card, measurement values and service report.
- Water treatment service and maintenance softwareMonthly visits, conductivity and hardness readings, consumables.
- Periodic maintenance tracking programMaintenance calendar and reminders.
- How to replace Excel for service and maintenance trackingMoving scattered spreadsheets into one system.
- How to write a service reportThe fields a report needs.